Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
J Arthroplasty ; 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38734325

RESUMEN

BACKGROUND: Conforming and congruent bearings in total knee arthroplasty (TKA) have rapidly increased due to the benefits of increased stability and the potential for replicating normal knee kinematics. However, limited data exist for these newly available bearings. This study evaluated revision-free survivorship and patient-reported outcome measures (PROMs) of a large granular database of primary TKAs using a single conforming bearing design. METHODS: A total of 1,306 consecutive primary TKAs performed using a single conforming bearing design (85% cemented and 15% cementless) were retrospectively reviewed. Kaplan-Meier (KM) survivorship estimates were calculated based on the latest clinical follow-up. The PROMs and minimal clinically important differences (MCIDs) were evaluated. A total of 93% of cases achieved minimum 1-year clinical follow-up (mean 3.5 years; range, 1 to 7), with a subset of 261 cases that achieved minimum 5-year follow-up (mean 5.8 years; range, 5 to 7). RESULTS: All-cause and aseptic KM survivorship estimates were 97.6 (95% CI [confidence interval], 97 to 99) and 98.1% (95% CI, 97 to 99) at 7.0 years. Revision-free survivorship did not differ by cemented or cementless fixation (98 versus 97%, P = 0.163). All PROM scores significantly improved from preoperative baseline (P < 0.001), and ≥ 86% of patients achieved MCIDs for Knee Society pain and Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) total scores. A total of 89% of cases reported their knees to 'sometimes or always' feel normal. For cases with minimum 5-year PROMs, 93% were 'very satisfied' or 'satisfied.' CONCLUSION: Conforming-bearing TKA demonstrated excellent survivorship up to 7.0 years. In addition, PROMs were comparable to other designs reported in the literature. While mid-term (mean 3.5-year) results are promising, long-term data are warranted on survivorship due to potential polyethylene wear in conforming bearings with more surface area in contact with articulating surfaces.

2.
J Arthroplasty ; 2024 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-38408715

RESUMEN

BACKGROUND: Cementless femoral fixation in total hip arthroplasty (THA) has increased in prevalence worldwide. However, cementless fixation in elderly patients is controversial due to the risks of periprosthetic fracture and aseptic loosening. This study evaluated outcomes in patients undergoing primary THA utilizing a cementless stem without a collar, comparing those less than 75 years to those older than 75 years. METHODS: Between 2011 and 2021, there were 2,605 cementless THAs performed by 4 surgeons utilizing a highly porous metal fixation surface without a collar and consistent clinical protocols. There were 469 patients who had an age ≥ 75 years. Revision rates, intraoperative fractures, and 90-day mortality were compared between cohorts. In the ≥ 75 year age group, there were more women, more American Society of Anesthesiologists physical status classification III or IV, a lower body mass index, and more kidney disease, osteoporosis, and thyroid disease (P ≤ .002). RESULTS: All-cause revision rates trended lower for the ≥75 year age group compared to < 75 year (1.9 versus 3.5%, P = .082) at 20-months of follow-up. Moreover, there was no difference in all-cause femoral component revisions comparing ≥ 75 to < 75 year age groups (1.5 versus 2.2%, P = .375), with only 3 of 10 femoral revisions due to aseptic loosening being in the ≥ 75 year age group. Intraoperative fracture (0.2 versus 0.5%, P = .701) and 90-day mortality (0.2 versus 0.1%, P = .460) did not differ between ≥ 75 and < 75 year age groups. CONCLUSIONS: Older patients had comparable revision rates compared to younger patients using cementless femoral fixation without a collar. Furthermore, there was no difference in 90-day mortality or intraoperative fracture rates. Study findings provide evidence for the safety and durability of cementless THA using collarless femoral stems in elderly patients ≥ 75 years of age. LEVEL OF EVIDENCE: III.

3.
J Arthroplasty ; 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38360280

RESUMEN

BACKGROUND: A core tenet of total knee arthroplasty (TKA) is that achieving more natural kinematics will lead to superior patient outcomes. Yet this relationship has not been proven for large representative cohorts of TKA patients because accurately measuring 3-dimensional TKA kinematics is time-consuming and expensive. But advanced imaging systems and machine learning-enhanced analysis software will soon make it practical to measure knee kinematics preoperatively and postoperatively in the clinic using radiographic methods. The purpose of this study was to assess the reported relationships between TKA kinematics and outcomes and distill those findings into a proposal for a clinically practical protocol for a clinical kinematic exam. METHODS: This study reviewed the recent literature relating TKA kinematics to patient outcomes. There were 10 studies that reported statistical associations between TKA kinematics and patient outcome scores utilizing a range of functional activities. We stratified these activities by the complexity of the radiographic examination to create a proposed examination protocol, and we generated a list of requirements and characteristics for a practical TKA clinical kinematic examination. RESULTS: Given considerations for a clinically practical kinematic exam, including equipment, time and other resources, we propose 3 exam levels. With basic radiographs, we suggest studying single-leg stance in extension, lunge or squat, and kneeling. For fluoroscopic systems with X-ray pulses up to 20 ms, we propose chair-rise or stair ascent to provide additional dynamic information. For fluoroscopic systems with X-ray pulses of less than 10 ms, we propose rapid open-chain knee flexion-extension to simulate the highly dynamic swing phase of gait. CONCLUSIONS: It is our hope that this proposed examination protocol spurs discussion and debate so that there can be a consensus approach to clinical examination of knee and TKA kinematics when the rapidly advancing hardware and software capabilities are in place to do so.

5.
J Arthroplasty ; 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38336307

RESUMEN

BACKGROUND: Leaving the patella unresurfaced in total knee arthroplasty (TKA) has increased significantly over the past decade in the United States, likely due to modern patella-friendly implants, complications with resurfacing, and the knowledge that historical studies were scientifically confounded. This study evaluated revision-free survivorship out to 8.5 years in a cohort of contemporary primary TKAs with patella-friendly femoral components and unresurfaced patellae. METHODS: A total of 1,053 consecutive primary TKAs with unresurfaced patellae were retrospectively reviewed. A selective patellar nonresurfacing protocol was used for all cases. Kaplan-Meier survivorship estimates were calculated based on patellar revision and the latest follow-up. An aggressive lateral patellar facetectomy was performed in 78% (823 of 1,053) of cases. The cohort was 62% women and 43% American Society of Anesthesiologists physical status classification I or II with a mean age and body mass index of 65 years (range, 35 to 94) and 35 kg/m2 (range, 18 to 65), respectively. RESULTS: A total of 4 (0.4%, 4 of 1,053) unresurfaced patellae were revised. Three were resurfaced as part of other procedures: 2 for global instability and one for aseptic loosening at a mean of 1.6 years; and one patella was resurfaced by an outside surgeon for unexplained pain. The all-cause revision-free survivorship estimate specifically related to the patella was 98.9% (95% confidence interval, 98 to 100) out to 8.5 years. No significant difference in survivorship was related to patellae with or without a lateral patellar facetectomy (99.5 versus 98.1%, P ≥ .191); however, 3 of 4 patellar revisions occurred in TKAs without a lateral patellar facetectomy (P = .035). CONCLUSIONS: The results of this study demonstrate excellent revision-free survivorship related to unresurfaced patellae, particularly when a lateral facetectomy was performed. These early to midterm results using modern patella-friendly femoral components are promising and comparable to resurfaced patellae in the literature. LEVEL OF EVIDENCE: IV.

6.
J Am Acad Orthop Surg ; 32(8): e396-e404, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38175997

RESUMEN

INTRODUCTION: Dislocation rates in patients who have fixed spinopelvic motion have been reported up to 20%. Few studies have directly compared dislocation rates in patients who have spine pathology undergoing total hip arthroplasty (THA) through different surgical approaches. This study compared postoperative dislocation rates in patients who had lumbar spine disease and underwent primary THA using a posterior or direct lateral approach. METHODS: Between 2011 and 2017, consecutive cohorts of primary THAs were retrospectively reviewed. One surgeon routinely used a posterior approach, while the other used a direct lateral approach. Chart and radiographic review were conducted to identify patients who had lumbar spine disease. Dislocations among cohorts with and without lumbar spine disease were compared by posterior and direct lateral approaches. RESULTS: The overall dislocation rate was 1.3% (15/1,198). The top four predictors of dislocation were presence of lumbar spine disease (odds ratio [OR] 5.0; P = 0.014), posterior surgical approach (OR, 6.5; P = 0.074), cases performed for fracture (OR, 4.4; P = 0.035), and women (OR, 4.6; P = 0.050). Dislocation rates among direct lateral approach patients who had lumbar spine pathology were significantly lower than posterior approach patients who had lumbar spine pathology (0.0% versus 3.6%; P = 0.011). DISCUSSION: Although dislocation rates were low in both groups, study results suggest that a direct lateral approach for primary THA may reduce postoperative dislocations for patients who have limited spinopelvic motion due to lumbar spine pathology. Furthermore, surgeons using the posterior approach might consider optimizing the femoral head to acetabular cup ratio in patients who have lumbar spine disease.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación de la Cadera , Luxaciones Articulares , Humanos , Femenino , Artroplastia de Reemplazo de Cadera/métodos , Estudios Retrospectivos , Luxaciones Articulares/cirugía , Acetábulo/cirugía , Vértebras Lumbares/cirugía , Luxación de la Cadera/epidemiología , Luxación de la Cadera/etiología , Luxación de la Cadera/cirugía
7.
J Arthroplasty ; 39(3): 632-637, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37717834

RESUMEN

BACKGROUND: Two related recent reports described high error rates for implant positioning and reduced implant survivorship in manual unicompartmental knee arthroplasty (MUKA) compared to robotic-assisted unicompartmental knee arthroplasty (RUKA). The present study scientifically replicated these reports by comparing MUKAs similarly performed by an experienced high-volume surgeon in similar patients using the same study methods as these reports. METHODS: A total of 216 consecutive MUKAs were retrospectively evaluated radiographically for achievement of implant positioning targets. Achievement of targets was compared to the published MUKA and RUKA outcomes and correlated with revision rates and patient-reported outcome measures. RESULTS: There were 20% of study MUKAs compared to 88.1% of comparison MUKAs (P < .001) and 31.4% of comparison RUKAs (P < .048) that failed to meet all 7 implant positioning targets. The MUKA revision rates were significantly lower in the study sample than for comparison MUKAs (3.2% versus 14.2%, P < .001). Implant survivorship was 91.7% (95% confidence interval 84.9, 98.5%) at 8.9 years compared to 70.0% (95% confidence interval 56.0, 80.0%) at 10.2 years, respectively. Most patient-reported outcome measures did not differ based on achievement of implant positioning targets (P ≥ .072). CONCLUSIONS: Present study findings indicate that observations in the 2 recent reports may not be generalizable to all UKA surgeons. Additional data on the relationship between implant positioning and revision as well as functional outcomes are needed to identify appropriate robotic arthroplasty applications.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Estudios Retrospectivos , Supervivencia , Osteoartritis de la Rodilla/cirugía , Procedimientos Quirúrgicos Robotizados/métodos , Medición de Resultados Informados por el Paciente , Resultado del Tratamiento , Articulación de la Rodilla/cirugía
8.
J Arthroplasty ; 39(5): 1304-1311, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37924992

RESUMEN

BACKGROUND: Tapered, fluted titanium (TFT) femoral stems have become the gold standard in revision total hip arthroplasty (rTHA). However, there is a paucity of data on TFT stem subsidence rates following aseptic rTHA. Subsidence can lead to instability, mechanical failure, leg-length discrepancy, and may require revision surgery. This study evaluated the incidences and predictors of TFT subsidence in aseptic rTHA. METHODS: A total of 102 TFT femoral stems of 4 designs were retrospectively reviewed. Stem subsidence was measured on digital radiographs taken immediately after surgery and at standard clinical follow-up. Patient characteristics, risk factors for subsidence, revision etiologies, and implant characteristics were recorded. Patient-reported outcome measures were also evaluated for a subset of cases. RESULTS: Overall, 12% of stems subsided >1 cm, and subsidence was minimal (<3 mm) in ≥64% of cases. From immediate postoperative to 1-month radiographic follow-up, 79% of stems subsided a mean of 2.9 mm (range, 0.1 to 12 mm). Beyond 1 month, subsidence was minimal for ≥77% of cases. In multivariate analyses, women and less femoral implant canal fill were associated with greater subsidence (P ≤ .034). The TFT stem design was not associated with early subsidence (P = .816). There were no modular junction fractures. There were 2 fractures and 2 subsidence-related revisions for aseptic loosening that occurred postoperatively. CONCLUSIONS: The amount of subsidence in TFT stems was low and was detectable in the early (less than 1 year) postoperative period. Maximizing TFT stem fill within the femoral canal appears to reduce the risk of subsidence without increasing femoral fracture rates and should be the goal with implantation of these devices. LEVEL OF EVIDENCE: IV-Case Series, No Control Group.

9.
J Arthroplasty ; 38(12): 2484-2491, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37595768

RESUMEN

BACKGROUND: Body mass index (BMI) cutoffs have been established for total knee arthroplasty (TKA) patients due to increased risk of medical complications in obese patients. However, evidence-based medical optimization may mitigate risk in these patients. This study examined the influence of BMI on patient-reported outcome measures (PROMs) following primary TKA with specialized perioperative optimization. METHODS: Between 2016 and 2020, 1,329 consecutive primary TKAs using standardized perioperative optimization were retrospectively reviewed. Patients were categorized into ordinal groups based on BMI in 5 kg/m2 increments (range, 17 to 61). Primary outcomes related to activity level, pain, function, and satisfaction were evaluated. BMI groups ≥35 had significantly lower age, more women, and higher prevalence of comorbidities (P ≤ .004). Mean follow-up was 1.7 years (range, 1 to 5 years). RESULTS: Each successive BMI group from 35 to ≥50 demonstrated continually greater improvement in pain with level walking and stair climbing (P ≤ .001), Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (P = .001), and greater satisfaction (P = .007). No patients who had a BMI ≥35 were revised for aseptic loosening, and rates of periprosthetic joint infection were not different between BMI groups (P = 1.000). CONCLUSION: Despite being more debilitated preoperatively, patients who had a BMI ≥35 experienced greater improvements in PROMs compared to patients who had lower BMI. Given the significant improvements in PROMs and quality of life in obese patients, with appropriate perioperative optimization, these patients should not be prohibited from having a TKA when appropriately indicated. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Humanos , Femenino , Artroplastia de Reemplazo de Rodilla/efectos adversos , Estudios Retrospectivos , Calidad de Vida , Obesidad/complicaciones , Obesidad/cirugía , Osteoartritis de la Rodilla/complicaciones , Medición de Resultados Informados por el Paciente , Dolor/cirugía , Articulación de la Rodilla/cirugía , Resultado del Tratamiento
10.
J Am Acad Orthop Surg ; 31(19): e834-e844, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37390317

RESUMEN

INTRODUCTION: Replicating native knee kinematics remains the ultimate goal of total knee arthroplasty (TKA). Technology, such as robotics, provides robust intraoperative data; however, no evidence-based targets currently exist for improved clinical outcomes. Furthermore, some surgeons target a rectangular flexion space in TKA unlike the native knee. This study evaluated the effect of in vivo flexion gap asymmetry on patient-reported outcome measures (PROMs) in contemporary TKA. METHODS: In vivo tibiofemoral joint space dimensions were measured during 129 TKAs using a calibrated tension device before and after complete posterior cruciate ligament resection. PROMs were compared based on the final dimensions and the change in flexion gap dimensions at 90° of flexion: (1) equal laxity, (2) lateral laxity, and (3) medial laxity. Groups did not differ by demographics ( P ≥ 0.347), clinical follow-up ( P = 0.134), tibiofemoral alignment ( P = 0.498), or preoperative PROMs ( P ≥ 0.093). Mean follow-up for the cohort was 1.5 years (range, 1-3). RESULTS: Pain with climbing stairs, pain while standing upright, and knees "always feeling normal" scores were superior for patients with equal or lateral laxity compared with medial laxity ( P ≤ 0.064). Pain with level walking, University of California Los Angeles activity level, KOOS JR, and satisfaction scores also tended to be superior for patients with equal or lateral laxity, although it lacked statistical significance ( P ≥ 0.111). DISCUSSION: Results of this study suggest that patients with either an equally tensioned rectangular flexion space or with later-flexion lateral laxity after posterior cruciate ligament resection may achieve superior PROMs. Findings support the clinical benefit of facilitating posterolateral femoral roll back in flexion, which mimics native knee kinematics and further helps define targets for advanced technology.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Inestabilidad de la Articulación , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Ligamento Cruzado Posterior , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Ligamento Cruzado Posterior/cirugía , Rodilla , Osteoartritis de la Rodilla/cirugía , Rango del Movimiento Articular , Fenómenos Biomecánicos , Inestabilidad de la Articulación/cirugía
11.
J Arthroplasty ; 38(7 Suppl 2): S245-S251, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37100094

RESUMEN

BACKGROUND: Advanced technologies, like robotics, provide enhanced precision for implanting total knee arthroplasty components; however, optimal component position and limb alignment remain unknown. This study sought to identify sagittal and coronal alignment targets that correlate with minimal clinically important differences (MCIDs) in patient-reported outcome measures (PROMs). METHODS: A total of 1,311 consecutive total knee arthroplasties were retrospectively reviewed. Posterior tibial slope (PTS), femoral flexion (FF), and tibio-femoral alignment (TFA) were measured radiographically. Patients were grouped based on whether they achieved multiple MCIDs for PROM scores. Classification and regression tree machine learning models were utilized to identify optimal alignment zones. The mean follow-up was 2.4 years (range, 1 to 11). RESULTS: The change in PTS and postoperative TFA were most predictive for achieving MCIDs in 90% of the models. Approximating native PTS within 4° correlated with MCID achievement and superior PROMs. Preoperative varus and neutral aligned knees were more likely to meet MCIDs and superior PROM scores when not overcorrected into valgus postoperatively (≥7°). Preoperative valgus-aligned knees correlated with MCID achievement when postoperative TFA was not overcorrected into substantial varus (<0°). Albeit less impactful, FF ≤ 7° correlated with MCID achievement and superior PROMs regardless of preoperative alignment. Sagittal and coronal alignment measurements had moderate to strong interactions in 13 of 20 models. CONCLUSION: Optimized PROM MCIDs correlated with approximating native PTS while maintaining similar preoperative TFA and incorporating moderate FF. Study findings demonstrate interactions between sagittal and coronal alignment which may optimize PROMs, highlighting the importance of three-dimensional implant alignment targets. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Estudios Retrospectivos , Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Tibia/cirugía
12.
J Arthroplasty ; 38(7S): S124-S130, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36791889

RESUMEN

BACKGROUND: Postoperative dislocation is considered the main drawback of posterior approach total hip arthroplasty (THA). Thinner highly cross-linked polyethylene and dual-mobility bearings allow maximizing femoral head diameter per a given cup size. This study evaluated dislocation rates as large femoral head bearings were introduced into a practice over an 11-year period. METHODS: A total of 1,511 consecutive primary THAs were retrospectively reviewed. Demographics, implant sizes, femoral head-acetabular cup ratio, and dislocation status were collected from the electronic medical record. Data were evaluated using time series analysis techniques as larger femoral heads, thinner polyethylene liners, and dual-mobility bearings were introduced. The cohort was 57% women with mean age and body mass index of 62 years (range, 13 to 93) and 31 kg/m2 (range, 13 to 54), respectively. RESULTS: The overall dislocation rate was 0.98%. Use of femoral head sizes ≥ 40 millimeters increased from 4% in the years 2010 to 2016 to 51% in the years 2017 to 2021, correlating with a 50% reduction in dislocation rate from 1.4% to 0.7% (P = .279). Also, no dislocations occurred in patients who had dual-mobility bearings or ≥ 40-millimeter femoral heads (P = .007). Twelve of 14 dislocations occurred in cases with head-cup ratio < 0.7 (P = .013). Thirteen of 14 dislocations were in women (P = .005). CONCLUSION: Maximizing the femoral head diameter per given cup size correlated with a decrease in dislocation rate in modern posterior approach THA. Furthermore, these results suggest that dual-mobility articulations should be reserved for high-risk patients or patients in whom a 40-millimeter femoral head is not possible. LEVEL OF EVIDENCE: IV-consecutive case series; no control group.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación de la Cadera , Prótesis de Cadera , Luxaciones Articulares , Humanos , Femenino , Masculino , Artroplastia de Reemplazo de Cadera/efectos adversos , Cabeza Femoral/cirugía , Prótesis de Cadera/efectos adversos , Estudios Retrospectivos , Diseño de Prótesis , Luxaciones Articulares/cirugía , Polietileno , Reoperación , Luxación de la Cadera/epidemiología , Luxación de la Cadera/etiología , Luxación de la Cadera/prevención & control , Falla de Prótesis
13.
J Arthroplasty ; 38(6S): S145-S150, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36791890

RESUMEN

BACKGROUND: Cementless fixation in total knee arthroplasty (TKA) is re-emerging due to improvements in biomaterials, surgical technique, and implant design. Albeit rare, failure of osseointegration typically occurs within the first 2 years, and limited data exist on survivorship of the modern cementless TKA designs. This study evaluated clinical survivorship of 2 contemporary cementless TKA designs at minimum 2-year follow-up. METHODS: A total of 627 cementless TKAs were performed up to July 2022. Three hundred thirty-nine cases were eligible for 2-year follow-up. Indications centered around bone quality and involved predominantly younger patients. The 2 designs consisted of tibial components with a highly porous titanium ingrowth surface, a central keel, and peripheral cruciform pegs with a porous cobalt-chromium femur. Survivorship estimates were calculated using right-censored non-parametric Kaplan-Meier methodologies. A total of 226 TKAs obtained minimum 2-year follow-up with a mean of 3.6 years (range, 2 to 10). RESULTS: The all-cause revision rate was 2.4% (8 of 339). The revision rate due to aseptic loosening was 0.6% (2 of 339) consisting of 2 femoral components. No tibial components were revised for aseptic loosening. Kaplan-Meier survivorship free from aseptic loosening was 99% (95% confidence interval 98 to 100) at a maximum of 10 years. CONCLUSION: These results demonstrate encouraging survivorship of cementless fixation in primary TKA with use of contemporary ingrowth biomaterials and modern implant designs. This particular tibial implant design with a highly porous titanium fixation surface, central keel, and peripheral cruciform pegs demonstrated excellent clinical survivorship without failure which may portend superior fixation. LEVEL OF EVIDENCE: IV-case series, no control group/historical control group.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Titanio , Fémur/cirugía , Materiales Biocompatibles , Reoperación , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento , Estudios de Seguimiento
14.
Arthroplast Today ; 19: 101082, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36691460

RESUMEN

Background: The link between tobacco consumption and wound complications following total knee arthroplasty (TKA) is well established. However, the effect of tobacco use on biologic fixation in cementless TKA remains unknown. This study evaluated the influence of tobacco use on the presence of radiolucent lines of tibial components in cementless TKA. Methods: A total of 293 consecutive cementless TKAs of 2 contemporary designs were retrospectively reviewed. Tibial radiolucent lines and component alignment were measured using an established measurement protocol. Patients with any history of tobacco use or active tobacco use (tobacco users) were compared to those with no history of tobacco use (tobacco nonusers). No significant differences which influenced outcomes were detected between the tobacco user and tobacco nonuser groups (P ≥ .071). Results: Radiolucent lines decreased from 1-month to latest follow-up (mean 2.5 years) in all 10 radiographic zones regardless of tobacco use (P ≤ .084). However, evaluating intrapatient change in radiolucent line width, the tobacco nonuser group had more radiolucent lines resolve by the latest follow-up in nearly all radiographic zones, although most differences did not reach statistical significance, except for anteroposterior zone 1 (-31% vs -19%, P = .022). No tibial components were revised for aseptic loosening. Conclusions: Results from this study suggest that any tobacco use prior to cementless TKA has the potential to hinder biologic fixation of tibial components. While no tibial components were revised for aseptic loosening, follow-up was relatively short at 2.5 years and therefore warrants further study to discern the effect of persistent radiolucent lines on long-term fixation.

15.
J Arthroplasty ; 38(3): 491-496, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36252746

RESUMEN

BACKGROUND: Leaving the patella unresurfaced in total knee arthroplasty (TKA) is increasing due to modern patella-friendly implants, awareness that complications are not uncommon with resurfacing, and knowledge that historical studies were scientifically confounded. This study examined the effect of selective patellar resurfacing on patient-reported outcome measures (PROMs) using modern implants and techniques in cohorts rigorously matched for demographics and osteoarthritis severity. METHODS: A total of 166 TKAs performed without patellar resurfacing were case-control matched to 166 TKAs with patella resurfacing. Case-control matching was based on demographics, American Society of Anesthesiology Physical Status, comorbidities, and osteoarthritis severity. No significant differences were observed between cohorts for demographics (P ≥ .347), comorbidities (P ≥ .443), or radiographic osteoarthritis severity (P ≥ .078). Radiographic alignment and prospectively collected PROMs were evaluated preoperatively and at latest clinical follow-up. RESULTS: Preoperatively, patellar tilt was less for the unresurfaced patella group (3 versus 4°, P = .003); however, postoperative patellar tilt was not different (3 versus 3°, P = .225). At a mean of 2.1 years follow-up (range, 1 to 7), University of California Los Angeles Activity Level was significantly higher for the unresurfaced patella group (6.3 versus 5.5, P = .002), but the mean group difference did not reach a minimal clinically important difference. There were no other significant differences in PROMs or reoperation rates between cohorts (P ≥ .135). CONCLUSION: In contemporary cruciate retaining and substituting TKA designs, not resurfacing the patella in select patients may achieve comparable PROMs and re-operation rates; and potentially greater activity level compared to patella resurfacing at early follow-up. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Rótula/cirugía , Osteoartritis de la Rodilla/cirugía , Resultado del Tratamiento , Estudios de Cohortes
16.
J Arthroplasty ; 37(10): 2090-2096, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35533823

RESUMEN

BACKGROUND: It remains unclear whether reimplantation of a patellar component during a two-stage revision for periprosthetic total knee arthroplasty infection (PJI) affects patient reported outcome measures (PROMs) or implant survivorship. The purpose of this study was to evaluate whether patellar resurfacing during reimplantation confers a functional benefit or increases implant survivorship after two-stage treatment for PJI. METHODS: Two-stage revisions for knee PJI performed by three surgeons at a single tertiary care center were reviewed retrospectively. All original patellar components and cement were removed during resection and the patella was resurfaced whenever feasible during reimplantation. PROMs, implant survivorship, and radiographic measurements (patellar tilt and displacement) were compared between knees reimplanted with a patellar component versus those without a patellar component. RESULTS: A total of 103 patients met the inclusion criteria. Forty-three patients (41.7%) underwent reimplantation with, and 60 patients (58.3%) without a patellar component. At a mean follow-up of 33.5 months, there were no significant differences in patient demographics or PROMs between groups (P ≥ .156). No significant differences were found in the estimated Kaplan-Meier all-cause, aseptic, or septic survivorship between groups (P ≥ .342) at a maximum of 75 months follow-up. There was no significant difference in the change (pre-resection to post-reimplant) of patellar tilt (P = .504) or displacement (P = .097) between the groups. CONCLUSION: Patellar resurfacing during knee reimplantation does not appear to meaningfully impact postoperative PROMs or survivorship. Given the risk of potential extensor mechanism complications with patellar resurfacing, surgeons may choose to leave the patella without an implant during total knee reimplantation and expect similar clinical outcomes. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Infecciones Relacionadas con Prótesis , Artritis Infecciosa/cirugía , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla/efectos adversos , Rótula/cirugía , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
17.
Artículo en Inglés | MEDLINE | ID: mdl-35389911

RESUMEN

BACKGROUND: Optimizing knee kinematics has the potential to increase patient satisfaction with total knee arthroplasty (TKA); however the ability to enact a particular kinematic pattern is variable and inconsistent. The purpose of this study was to determine whether intraoperative contact forces were predictive and can potentially drive a particular kinematic pivot pattern. METHODS: All TKAs used sensor-embedded tibial trials to intraoperatively measure medial and lateral compartment forces, and the associated condylar contact points were used to calculate kinematic pivot patterns between preceding flexion angles. RESULTS: After exclusions, 157 TKAs were analyzed. For posterior cruciate ligament-intact TKAs, no predictors of lateral pivot were identified in early flexion; however, increased medial compartment force and increased lateral compartment force were predictors of medial and lateral pivots for mid and late flexion, respectively (P ≤ 0.037). For posterior cruciate ligament-resected TKAs, increased lateral compartment force was a predictor of lateral pivot in early and midflexion (P ≤ 0.031) but not late flexion. CONCLUSION: The tibiofemoral compartment with greater contact force exhibited less anteroposterior translation at certain flexion ranges and correlated with kinematic pivot patterns. This information may benefit surgeons who are attempting to facilitate a particular kinematic pattern. Further research is recommended to confirm that intraoperative kinematics correlate with weight-bearing postoperative kinematics and clinical outcomes.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Ligamento Cruzado Posterior , Fenómenos Biomecánicos , Humanos , Articulación de la Rodilla/cirugía , Ligamento Cruzado Posterior/cirugía , Rango del Movimiento Articular
18.
Artículo en Inglés | MEDLINE | ID: mdl-35389915

RESUMEN

INTRODUCTION: The degree of osteoarthritis (OA) acceptable to leave in a native patella during unresurfaced total knee arthroplasty (TKA) remains unknown. This study's purpose was to examine the effect of patellofemoral OA severity on patient-reported outcome measures (PROMs) in primary TKAs performed without patellar resurfacing. METHODS: One hundred ninety-three primary TKAs performed without patellar resurfacing were retrospectively reviewed. Preoperative patellofemoral OA severity was graded on severity, marginal osteophytes, joint space narrowing, and chondral damage using accepted grading systems. Patellar tilt and tibiofemoral alignment were measured radiographically. PROMs were evaluated at a minimum of 1-year follow-up. RESULTS: In multivariate regression, preoperative lateral patella Kellgren-Lawrence grade ≥2 was associated with superior change in Knee Society Score pain with level walking, higher absolute change in Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (P ≤ 0.029), and knees ?always feeling normal" (odds ratio [OR] 3.12; P = 0.005). Osteoarthritis Research Society International atlas grades and Outerbridge classification scores did not significantly influence PROMs. DISCUSSION: Worse preoperative OA severity in the lateral patellar facet, graded with the Kellgren-Lawrence system, predicted superior knee-specific PROMs in patients with unresurfaced patellae after contemporary TKA. This observation supports the clinical finding that patients with more severe OA have optimized patient outcomes and highlights the minimal contribution of patella OA to knee function after primary TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Humanos , Osteoartritis de la Rodilla/cirugía , Rótula/cirugía , Medición de Resultados Informados por el Paciente , Estudios Retrospectivos , Resultado del Tratamiento
19.
J Arthroplasty ; 37(8): 1501-1504, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35283237

RESUMEN

Musculotendinous deficiencies related to iliopsoas tendinitis and abductor mechanism disruption following total hip arthroplasty (THA) are frequently under diagnosed and can be frustrating to surgeons and devastating to patients with painful THAs with normal appearing radiographs. Current peer-reviewed evidence is presented for diagnosis and treatment options for these two musculotendinous deficiencies. While these musculotendinous deficiencies are treatable, prevention during the primary THA is ideal, and special attention should be taken into consideration for optimized acetabular cup size and position, optimized hip biomechanics, and preservation and protection of the abductor tendon insertion to the greater trochanter.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Tendinopatía , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Fémur/cirugía , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Estudios Retrospectivos , Tendinopatía/diagnóstico , Tendinopatía/etiología , Tendinopatía/terapia
20.
J Arthroplasty ; 37(7S): S685-S691, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35227535

RESUMEN

BACKGROUND: Highly cross-linked polyethylene with vitamin E (VE-HXLPE) has shown superior tribological properties and has been rapidly adopted in total hip arthroplasty. However, the majority of studies compare VE-HXLPE to conventional or moderately cross-linked polyethylene using standard femoral head sizes. This study's purpose was 2-fold: (1) compare radiographic femoral head penetration (FHP) between VE-HXLPE and HXLPE and (2) evaluate FHP in large femoral heads ≥40 mm. METHODS: One hundred forty-two consecutive primary total hip arthroplasties using ceramic femoral heads (n = 84 VE-HXLPE; n = 58 HXLPE) in a single implant system were retrospectively reviewed. FHP was measured radiographically utilizing Martell method at 4-week, 1-year, and latest radiographs. FHP, cup position, and demographic variables were compared between VE-HXLPE and HXLPE liners. RESULTS: Median linear FHP was lower for VE-HXLPE compared to HXLPE during the initial "bedding-in" period between 4-week and 1-year (0.383 vs 0.551 mm, P = .650) and between 1-year and latest follow-up (0.131 vs 0.270 mm/y, P = .636) although without statistical significance. Acetabular cup inclination and anteversion did not influence linear or volumetric FHP (P ≥ .204). Large femoral heads (≥40 mm) were predictive of higher FHP during the early bedding-in period (P ≤ .025) but did not have an effect beyond 1 year in multivariate regression with numbers available. No radiographic osteolysis was observed in any case. CONCLUSION: These findings support others that VE-HXLPE is the optimal polyethylene bearing surface to minimize FHP during the bedding-in period and beyond. Surprisingly, large ceramic femoral heads appear to influence FHP during the initial bedding-in period but do not increase FHP beyond 1 year. Further longer term follow-up remains warranted. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/métodos , Cabeza Femoral/cirugía , Estudios de Seguimiento , Humanos , Polietileno , Diseño de Prótesis , Falla de Prótesis , Estudios Retrospectivos , Vitamina E
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...